polysulfoethyl a column Search Results


90
PolyLC INC 100 3 4.6-mm id polysulfoethyl a strong cation exchange column
100 3 4.6 Mm Id Polysulfoethyl A Strong Cation Exchange Column, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/100+3+4+6+mm+id+polysulfoethyl+a+strong+cation+exchange+column/pm17023561-58-4-14
Average 90 stars, based on 1 article reviews
100 3 4.6-mm id polysulfoethyl a strong cation exchange column - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC cation exchange column scx; polysulfoethylaspartamide column size: 200 å
Cation Exchange Column Scx; Polysulfoethylaspartamide Column Size: 200 å, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/semipreparative+scx+column++polysulfoethyl+a++9+4+mm+inner+diameter+200+mm+length++5+mm+particle+size++200+a%CC%8A+pore+size/pm18686298-55-6-19
Average 90 stars, based on 1 article reviews
cation exchange column scx; polysulfoethylaspartamide column size: 200 å - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC polysulfoethyl column (, × 200 å)
Polysulfoethyl Column (, × 200 å), supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/polysulfoethyl+a+column/pmc10725172-155-36-47
Average 90 stars, based on 1 article reviews
polysulfoethyl column (, × 200 å) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC cation-exchange chromatography polysulfoethyl a
Cation Exchange Chromatography Polysulfoethyl A, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/cation+exchange+column+polysulfoethyl+a/pm19208757-273-9-13
Average 90 stars, based on 1 article reviews
cation-exchange chromatography polysulfoethyl a - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC 9.4 by particle polysulfoethyl a strong cation exchange (scx) column
9.4 By Particle Polysulfoethyl A Strong Cation Exchange (Scx) Column, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/9+4+by+particle+polysulfoethyl+a+strong+cation+exchange++scx++column/pmc08699897-50-12-20
Average 90 stars, based on 1 article reviews
9.4 by particle polysulfoethyl a strong cation exchange (scx) column - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC 2.1-mm polysulfoethyl a ion-exchange column
2.1 Mm Polysulfoethyl A Ion Exchange Column, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/2+1+mm+polysulfoethyl+a+ion+exchange+column/pmc03309362-165-17-21
Average 90 stars, based on 1 article reviews
2.1-mm polysulfoethyl a ion-exchange column - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC polysulfoethyl a spin column sem hil-scx
Polysulfoethyl A Spin Column Sem Hil Scx, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/polysulfoethyl+a+spin+column+sem+hil+scx/10__1074_slash_mcp__m700399___mcp200-95-8-14
Average 90 stars, based on 1 article reviews
polysulfoethyl a spin column sem hil-scx - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC 2.1 mm×200 polysulfoethyl atm column
2.1 Mm×200 Polysulfoethyl Atm Column, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/4+6+mm+200+mm+polysulfoethyl+a+cationexchange+chromatography+column/pmc03187790-196-4-7
Average 90 stars, based on 1 article reviews
2.1 mm×200 polysulfoethyl atm column - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC scx column polysulfoethyl a 150×3 5 um, 200 a
Scx Column Polysulfoethyl A 150×3 5 Um, 200 A, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/scx+column+polysulfoethyl+a+150%C3%973+5+um++200+a/pm20060445-62-9-12
Average 90 stars, based on 1 article reviews
scx column polysulfoethyl a 150×3 5 um, 200 a - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC strong cation-exchange spin columns polysulfoethyl a resin, 300 å
Strong Cation Exchange Spin Columns Polysulfoethyl A Resin, 300 å, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/strong+cation+exchange+spin+columns+polysulfoethyl+a+resin+300+%C3%A5/pmc04380852-168-10-21
Average 90 stars, based on 1 article reviews
strong cation-exchange spin columns polysulfoethyl a resin, 300 å - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC scx column polysulfoethyl a, beads, 200 å pore size; 2
Simplified schematic diagram of the plumbing for liquid flow through the HPLC, autosampler, UV detector flow cell, <t>SCX</t> and RP columns. The flow paths that are used for the separations described in this article are all shown. All tubing is 1/16” outer diameter (OD) PEEK, with varied inner diameters, with the exception that PEEKsil tubing (also 1/16” OD) is used for all sample flow paths. Tubing was obtained primarily from Michrom and also from Upchurch Scientific (Seattle, WA). (A) Flow paths for sample introduction and <t>SCX</t> <t>column</t> stabilization, immediately prior to SCX separation are shown. Abbreviations: ASV, autosampler valve; HPLC V1, HPLC valve 1; mix 2, mixer 2 (for solvents C and D); HPLC V2, HPLC valve 2; UV, UV detector flow cell. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction into the (100 μl) sample loop, and 2) flow from pumps C and D (not shown for clarity), through mixer 2, for stabilization of solvent flow and pressure through the SCX column prior to the SCX separation. (B) Flow path during the SCX separation, which no longer involves sample introduction. To enter this stage following that shown in panel A, HPLC valve 1 switches, resulting in reversal of the sample flow back out of the sample loop and onto the SCX column. Concurrent to the switching of valve 1, the autosampler automatically suspends the fraction collection tool above the vials (Fig. 1B), in order to collect the eluate from the SCX column. The fraction collection tool is automatically moved to a fresh vial every 2.0 min, resulting in collection of 24 × 400 μl fractions. The SCX gradient, consisting of solvents C and D (see the text and Fig. 2A), is applied, resulting in peptide separation throughout the gradient. (C) Flow paths for sample introduction immediately prior to reversed phase (RP) separation; abbreviations: MSV, valve mounted on the mass spectrometer; mix 1, mixer 1 (for solvents A and B); cp tp, capillary peptide trap (polymeric); and AC, C18 reversed-phase, capillary-scale (1/16″ OD) analytical column. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction onto the peptide trap (cp tp) followed by desalting of the captured peptides, and 2) flow from pumps A and B (not shown for clarity), through mixer 1, for stabilization of solvent flow and pressure through the C18 analytical column (AC). The high voltage (1.8 kV) is manually activated at the start of this stage using the tune page, which is part of the control software for the mass spectrometer. (D) Flow path during the reversed-phase separation, which no longer involves sample introduction. To enter this stage following that shown in panel C, the valve mounted on the mass spectrometer switches, resulting in reversal of the solvent flow back through the peptide trap, gradient elution of the peptides off of the peptide trap, their separation in the analytical column, elution, and ionization in the ESI source, just prior to introduction into the mass spectrometer.
Scx Column Polysulfoethyl A, Beads, 200 å Pore Size; 2, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/scx+column+polysulfoethyl+a++beads++200+%C3%A5+pore+size++2/pmc02710416-120-1-16
Average 90 stars, based on 1 article reviews
scx column polysulfoethyl a, beads, 200 å pore size; 2 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
PolyLC INC 2.1 mm by 20 cm polysulfoethyl a column
Simplified schematic diagram of the plumbing for liquid flow through the HPLC, autosampler, UV detector flow cell, <t>SCX</t> and RP columns. The flow paths that are used for the separations described in this article are all shown. All tubing is 1/16” outer diameter (OD) PEEK, with varied inner diameters, with the exception that PEEKsil tubing (also 1/16” OD) is used for all sample flow paths. Tubing was obtained primarily from Michrom and also from Upchurch Scientific (Seattle, WA). (A) Flow paths for sample introduction and <t>SCX</t> <t>column</t> stabilization, immediately prior to SCX separation are shown. Abbreviations: ASV, autosampler valve; HPLC V1, HPLC valve 1; mix 2, mixer 2 (for solvents C and D); HPLC V2, HPLC valve 2; UV, UV detector flow cell. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction into the (100 μl) sample loop, and 2) flow from pumps C and D (not shown for clarity), through mixer 2, for stabilization of solvent flow and pressure through the SCX column prior to the SCX separation. (B) Flow path during the SCX separation, which no longer involves sample introduction. To enter this stage following that shown in panel A, HPLC valve 1 switches, resulting in reversal of the sample flow back out of the sample loop and onto the SCX column. Concurrent to the switching of valve 1, the autosampler automatically suspends the fraction collection tool above the vials (Fig. 1B), in order to collect the eluate from the SCX column. The fraction collection tool is automatically moved to a fresh vial every 2.0 min, resulting in collection of 24 × 400 μl fractions. The SCX gradient, consisting of solvents C and D (see the text and Fig. 2A), is applied, resulting in peptide separation throughout the gradient. (C) Flow paths for sample introduction immediately prior to reversed phase (RP) separation; abbreviations: MSV, valve mounted on the mass spectrometer; mix 1, mixer 1 (for solvents A and B); cp tp, capillary peptide trap (polymeric); and AC, C18 reversed-phase, capillary-scale (1/16″ OD) analytical column. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction onto the peptide trap (cp tp) followed by desalting of the captured peptides, and 2) flow from pumps A and B (not shown for clarity), through mixer 1, for stabilization of solvent flow and pressure through the C18 analytical column (AC). The high voltage (1.8 kV) is manually activated at the start of this stage using the tune page, which is part of the control software for the mass spectrometer. (D) Flow path during the reversed-phase separation, which no longer involves sample introduction. To enter this stage following that shown in panel C, the valve mounted on the mass spectrometer switches, resulting in reversal of the solvent flow back through the peptide trap, gradient elution of the peptides off of the peptide trap, their separation in the analytical column, elution, and ionization in the ESI source, just prior to introduction into the mass spectrometer.
2.1 Mm By 20 Cm Polysulfoethyl A Column, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/polysulfoethyl+a+column/2+1+mm+by+20+cm+polysulfoethyl+a+column/pmc00240687-62-46-49
Average 90 stars, based on 1 article reviews
2.1 mm by 20 cm polysulfoethyl a column - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Simplified schematic diagram of the plumbing for liquid flow through the HPLC, autosampler, UV detector flow cell, SCX and RP columns. The flow paths that are used for the separations described in this article are all shown. All tubing is 1/16” outer diameter (OD) PEEK, with varied inner diameters, with the exception that PEEKsil tubing (also 1/16” OD) is used for all sample flow paths. Tubing was obtained primarily from Michrom and also from Upchurch Scientific (Seattle, WA). (A) Flow paths for sample introduction and SCX column stabilization, immediately prior to SCX separation are shown. Abbreviations: ASV, autosampler valve; HPLC V1, HPLC valve 1; mix 2, mixer 2 (for solvents C and D); HPLC V2, HPLC valve 2; UV, UV detector flow cell. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction into the (100 μl) sample loop, and 2) flow from pumps C and D (not shown for clarity), through mixer 2, for stabilization of solvent flow and pressure through the SCX column prior to the SCX separation. (B) Flow path during the SCX separation, which no longer involves sample introduction. To enter this stage following that shown in panel A, HPLC valve 1 switches, resulting in reversal of the sample flow back out of the sample loop and onto the SCX column. Concurrent to the switching of valve 1, the autosampler automatically suspends the fraction collection tool above the vials (Fig. 1B), in order to collect the eluate from the SCX column. The fraction collection tool is automatically moved to a fresh vial every 2.0 min, resulting in collection of 24 × 400 μl fractions. The SCX gradient, consisting of solvents C and D (see the text and Fig. 2A), is applied, resulting in peptide separation throughout the gradient. (C) Flow paths for sample introduction immediately prior to reversed phase (RP) separation; abbreviations: MSV, valve mounted on the mass spectrometer; mix 1, mixer 1 (for solvents A and B); cp tp, capillary peptide trap (polymeric); and AC, C18 reversed-phase, capillary-scale (1/16″ OD) analytical column. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction onto the peptide trap (cp tp) followed by desalting of the captured peptides, and 2) flow from pumps A and B (not shown for clarity), through mixer 1, for stabilization of solvent flow and pressure through the C18 analytical column (AC). The high voltage (1.8 kV) is manually activated at the start of this stage using the tune page, which is part of the control software for the mass spectrometer. (D) Flow path during the reversed-phase separation, which no longer involves sample introduction. To enter this stage following that shown in panel C, the valve mounted on the mass spectrometer switches, resulting in reversal of the solvent flow back through the peptide trap, gradient elution of the peptides off of the peptide trap, their separation in the analytical column, elution, and ionization in the ESI source, just prior to introduction into the mass spectrometer.

Journal:

Article Title: Comprehensive proteomic analysis of Schizosaccharomyces pombe by two-dimensional HPLC-tandem mass spectrometry

doi: 10.1016/j.ymeth.2009.02.023

Figure Lengend Snippet: Simplified schematic diagram of the plumbing for liquid flow through the HPLC, autosampler, UV detector flow cell, SCX and RP columns. The flow paths that are used for the separations described in this article are all shown. All tubing is 1/16” outer diameter (OD) PEEK, with varied inner diameters, with the exception that PEEKsil tubing (also 1/16” OD) is used for all sample flow paths. Tubing was obtained primarily from Michrom and also from Upchurch Scientific (Seattle, WA). (A) Flow paths for sample introduction and SCX column stabilization, immediately prior to SCX separation are shown. Abbreviations: ASV, autosampler valve; HPLC V1, HPLC valve 1; mix 2, mixer 2 (for solvents C and D); HPLC V2, HPLC valve 2; UV, UV detector flow cell. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction into the (100 μl) sample loop, and 2) flow from pumps C and D (not shown for clarity), through mixer 2, for stabilization of solvent flow and pressure through the SCX column prior to the SCX separation. (B) Flow path during the SCX separation, which no longer involves sample introduction. To enter this stage following that shown in panel A, HPLC valve 1 switches, resulting in reversal of the sample flow back out of the sample loop and onto the SCX column. Concurrent to the switching of valve 1, the autosampler automatically suspends the fraction collection tool above the vials (Fig. 1B), in order to collect the eluate from the SCX column. The fraction collection tool is automatically moved to a fresh vial every 2.0 min, resulting in collection of 24 × 400 μl fractions. The SCX gradient, consisting of solvents C and D (see the text and Fig. 2A), is applied, resulting in peptide separation throughout the gradient. (C) Flow paths for sample introduction immediately prior to reversed phase (RP) separation; abbreviations: MSV, valve mounted on the mass spectrometer; mix 1, mixer 1 (for solvents A and B); cp tp, capillary peptide trap (polymeric); and AC, C18 reversed-phase, capillary-scale (1/16″ OD) analytical column. Two flow paths, marked by arrows, are active at this stage: 1) Flow of the sample, from the syringe, for sample introduction onto the peptide trap (cp tp) followed by desalting of the captured peptides, and 2) flow from pumps A and B (not shown for clarity), through mixer 1, for stabilization of solvent flow and pressure through the C18 analytical column (AC). The high voltage (1.8 kV) is manually activated at the start of this stage using the tune page, which is part of the control software for the mass spectrometer. (D) Flow path during the reversed-phase separation, which no longer involves sample introduction. To enter this stage following that shown in panel C, the valve mounted on the mass spectrometer switches, resulting in reversal of the solvent flow back through the peptide trap, gradient elution of the peptides off of the peptide trap, their separation in the analytical column, elution, and ionization in the ESI source, just prior to introduction into the mass spectrometer.

Article Snippet: The SCX column (polysulfoethyl A, 5 μM beads, 200 Å pore size; 2 × 150 mm, PolyLC, Inc., Columbia, MD) is prepared for the SCX separation by washing with 40:40:20 isopropanol:acetonitrile:H 2 0 (40:40:20 wash solvent) for 50 min at a flow rate of 200 μl/min.

Techniques: Solvent, Mass Spectrometry, Control, Software